Test ID MCLNR MayoComplete Lung Rearrangements, Rapid Test, Tumor
Ordering Guidance
Multiple oncology (cancer) gene panels are available. For more information see Hematology, Oncology, and Hereditary Test Selection Guide.
Necessary Information
A pathology report (final or preliminary), at minimum containing the following information, must accompany specimen for testing to be performed:
1. Patient name
2. Block number-must be on all blocks, slides, and paperwork (can be handwritten on the paperwork)
3. Tissue collection date
4. Source of the tissue
Specimen Required
This assay requires at least 10% tumor nuclei.
-Preferred amount of tumor area with sufficient percent tumor nuclei: tissue 36 mm(2)
-Minimum amount of tumor area: tissue 18 mm(2)
-These amounts are cumulative over up to 10 unstained slides and must have adequate percent tumor nuclei.
-Tissue fixation: 10% neutral buffered formalin, not decalcified
Preferred: Submit 3, if available, or 2 of the following specimens.
Acceptable: Submit at least one of the following specimens.
Specimen Type: Tissue block
Collection Instructions: Submit a formalin-fixed, paraffin-embedded tissue block with acceptable amount of tumor tissue.
Specimen Type: Tissue slide
Slides: 1 Hematoxylin and eosin-stained and 10 unstained
Collection Instructions:
Submit the followings slides:
1 Slide stained with hematoxylin and eosin
AND
10 Unstained, nonbaked slides with 5-micron thick sections of the tumor tissue.
Note: The total amount of required tumor nuclei can be obtained by scraping up to 10 slides from the same block.
Additional Information: Unused unstained slides will not be returned.
Specimen Type: Cytology slide (direct smears or ThinPrep)
Slides: 1 to 3 Slides
Collection Instructions: Submit 1 to 3 slides stained and coverslipped with a total of 5000 nucleated cells (preferred) or at least 3000 nucleated cells (minimum).
Note: Glass coverslips are preferred; plastic coverslips are acceptable but will result in longer turnaround times.
Additional Information: Cytology slides will not be returned. An image of the slides will be stored per regulatory requirements.
Useful For
Identifying lung tumors that may respond to targeted therapies by simultaneously assessing multiple genes involved in rearrangements resulting in fusion transcripts
Diagnosing and managing patients with lung cancer
Additional Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
SLIRV | Slide Review in MG | No | Yes |
Testing Algorithm
When this test is ordered, slide review will always be performed at an additional charge.
Special Instructions
Method Name
Polymerase Chain Reaction (PCR)
Reporting Name
MayoComplete Lung RearrangementsSpecimen Type
VariesSpecimen Minimum Volume
See Specimen Required
Specimen Stability Information
Specimen Type | Temperature | Time |
---|---|---|
Varies | Ambient (preferred) | |
Refrigerated |
Reference Values
An interpretive report will be provided.
Day(s) Performed
Monday through Friday
Report Available
4 to 8 daysPerforming Laboratory

Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81449
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
MCLNR | MayoComplete Lung Rearrangements | 73977-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
618280 | Result | 82939-0 |
618281 | Interpretation | 69047-9 |
618282 | Additional Information | 48767-8 |
618283 | Specimen | 31208-2 |
618284 | Tissue ID | 80398-1 |
618285 | Method | 85069-3 |
618286 | Disclaimer | 62364-5 |
618287 | Released By | 18771-6 |